Ring Pump RP-HX series : Pump head replacement type, Stepper motor drive

- The world's smallest level flow rate.
- Changing the tube is possible by replacement of the pumphead.
- A wide range of flow levels is possible by using different pumphead.
- Docking of the pumphead can be done in one action. No screw is necessary.
- A stepper motor is used for driving the pump. The motor controller for exclusive use is sold separately.
( RE-C100, RE-C500/C501, RE-C600 ) - An optional driver board for stepper motor control is available.

- Autoclave sterilizable pumphead is available.
- 10 times autoclave sterilization with 121 degrees Celsius, 25 minutes is possible.
- Color of the pumphead cover change to black, and the wire length change to 1,150 mm.
| Download |
|---|
| Catalog (PDF) |
| Outline drawing (PDF) |
| 3D CAD data (STEP) |
| 2D CAD data (DXF) |
| Model No. | Model No. of pumphead |
Autoclave sterilizable pumphead |
Wire length L (mm) / ∗1 Connector |
Discharge rate (µL/min) |
Tube | |
|---|---|---|---|---|---|---|
| Material | IDxOD (mm) |
|||||
| Used with Motor controller RE-C100 and RE-C600 (without connector) Pumphead is not autoclave sterilizable. |
||||||
| RP-HXP5S-P4A-DC3VS | RK-HXP5S | No | 15 cm / Without Molex connector |
2 - 400 | Silicone | 0.5 x 1.5 |
| RP-HX01S-1A-DC3VS | RK-HX01S | 5 - 1,000 | 1.0 x 2.0 |
|||
| RP-HXP5F-P25A-DC3VS | RK-HXP5F | 115 cm / Without Molex connector |
2 - 350 | Phar- Med BPT |
0.5 x 1.5 |
|
| Used with Motor controller RE-C100 and RE-C600 (without connector)Pumphead is autoclave sterilizable. | ||||||
| RP-HXP5S-P4E-DC3VS | RK- HXP5S-C |
Yes | 115 cm / Without Molex connector |
2 - 400 | Silicone | 0.5 x 1.5 |
| RP-HX01S-1H-DC3VS | RK- HX01S-D |
5 - 1,000 | 1.0 x 2.0 |
|||
| Used with Motor controller RE-C500/C501 and RE-C600 (with connector) Pumphead is not autoclave sterilizable. |
||||||
| RP-HXP5S-P4G-DC3VS | RK-HXP5S | No | 65 cm / With connector |
2 - 400 | Silicone | 0.5 x 1.5 |
| RP-HX01S-1J-DC3VS | RK-HX01S | 5 - 1,000 | 1.0 x 2.0 |
|||
| RP-HXP5S-P4H-DC3VS | RK-HXP5S | 215 cm / With Molex connector |
2 - 400 | 0.5 x 1.5 |
||
| RP-HX01S-1K-DC3VS | RK-HX01S | 5 - 1,000 | 1.0 x 2.0 |
|||
| Used with Motor controller RE-C500/C501 and RE-C600 (with connector)Pumphead is autoclave sterilizable. | ||||||
| RP-HXP5S-P4J-DC3VS | RK- HXP5S-C |
Yes | 215 cm / With Molex connector |
2 - 400 | Silicone | 0.5 x 1.5 |
| RP-HX01S-1L-DC3VS | RK- HX01S-D |
5 - 1,000 | 1.0 x 2.0 |
|||
| Motor driver board BD202411-Q can be used. (Coming with JST connector for connecting to the driver board.) Pump head does not support autoclave sterilization. |
||||||
| RP-HXP5S-P4A-DC24VS | RK-HXP5S | No | 65 cm / With JST connector |
2 ~ 400 | Silicone | 0.5 x 1.5 |
| RP-HX01S-1A-DC24VS | RK-HX01S | 5 ~ 1,000 | 1.0 x 2.0 | |||
| Motor driver board BD202411-Q can be used. (Coming with JST connector for connecting to the driver board.) Pump head supports autoclave sterilization. |
||||||
| RP-HXP5S-P4B-DC24VS | RK-HXP5S-C | Yes | 215 cm / With JST connector |
2 ~ 400 | Silicone | 0.5 x 1.5 |
| RP-HX01S-1B-DC24VS | RK-HX01S-D | 5 ~ 1,000 | 1.0 x 2.0 | |||
|
∗1. Connection to certain motor controllers requires a Molex connector (referred to as "Molex connector"). Connection to the motor driver board requires a JST connector (referred to as "JST connector"). ∗1. The pump with a connector is required for use with the motor controller RE-C500/C501. ∗1. The pump without connectors can be used with RE-C100. ∗1. RE-C600 can be used with or without connector. |
||||||
| Model No. | With RE-C100 (µL/min) | With RE-C500,C501 (µL/min) |
|
|---|---|---|---|
| 1/4 micro-step | 1/8 micro-step | ||
| RP-HXP5S-P4A-DC3VS | 5 - 400 | 2.5 - 200 | 2 - 400 |
| RP-HX01S-1A-DC3VS | 12 - 1,000 | 6 - 500 | 5 - 1,000 |
| RP-HXP5F-P25A-DC3VS | 4 - 350 | 2 - 180 | 2 - 350 |
| RP-HXP5S-P4E-DC3VS | 5 - 400 | 2.5 - 200 | 2 - 400 |
| RP-HX01S-1H-DC3VS | 12 - 1,000 | 6 - 500 | 5 - 1,000 |

The pump head can be attached to the base unit by rotating the pump head 180 degrees so that
the tube is facing downwards.

Stepper Motor Controller and Driver Board
This series is driven by a stepper motor.
To operate the stepper motor, a dedicated motor controller or driver board is required.
We offer the following motor controllers and driver board as a separately sold option. Please contact us if needed.
★ To use the driver board, you will need a pump equipped with wiring that includes
a JST connector compatible with the driver board (e.g., RP-HX***-***-DC24VS).
- Stepper motor controller for RP-HX, RP-TX, RP-QⅡB/C and RP-QⅢB/C series
- Only one pump can be connected to the RE-C600.
- Various pump operation sequences can be programmed using a PC connected to the RE-C600.
- The pump can be stopped at a specified number of revolutions up to 30 revolutions,
and a fixed discharge volume can be performed at a specified multiple
of the discharge volume per revolution.
(Discharge volume data for one rotation is attached to the pump) - The program data of the operation sequence can be saved in RE-C600 and the pump can be operated without connecting to the PC.
- Both with and without connector of motor wiring can be used.
- Stepper motor controller for RP-HX, RP-TX, RP-QⅡB/C and RP-QⅢB/C series
- A PC connected to the RE-C500 can control various pump operations.
- Control 6 pumps with RE-C500
- Up to 12 pumps can be controlled individually by adding one RE-C501.
- Various pump operation sequences can be programmed.
- The program data of the operation sequence can be saved in RE-C500 and the pump can be operated without connecting to the PC.
- When connecting multiple pumps, different types of pumps can be mixed.
Motor controller RE-C100 and Frequency counter RE-F100
- RE-C100 is a stepper motor controller dedicated to the RP-HX / TX series.
- Motor start / stop, forward / reverse rotation, and rotation speed adjustment are possible
- The RE-F100 is a frequency counter that connects to the RE-C100 and displays the pulse frequency for setting the rotation speed.
Stepper Motor Driver Board BD202411-Q

- A driver board used to connect the motor and power supply, and to control the motor via external control signals.
- Please prepare your own control device to send the control signals.
- A DC 24V, 1A power supply is required. Please use a DC power source, such as a DC power supply unit or AC adapter.